From: Shengjiu Wang shengjiu.wang@nxp.com
commit 1e060a453c8604311fb45ae2f84f67ed673329b4 upstream.
After suspend & resume, wm8960_hw_params may be called when bias_level is not SND_SOC_BIAS_ON, then wm8960_configure_clocking is not called. But if sample rate is changed at that time, then the output clock rate will be not correct.
So judgement of bias_level is SND_SOC_BIAS_ON in wm8960_hw_params is not necessary and it causes above issue.
Fixes: 3176bf2d7ccd ("ASoC: wm8960: update pll and clock setting function") Signed-off-by: Shengjiu Wang shengjiu.wang@nxp.com Acked-by: Charles Keepax ckeepax@opensource.cirrus.com Link: https://lore.kernel.org/r/1587468525-27514-1-git-send-email-shengjiu.wang@nx... Signed-off-by: Mark Brown broonie@kernel.org Signed-off-by: Greg Kroah-Hartman gregkh@linuxfoundation.org --- sound/soc/codecs/wm8960.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)
diff --git a/sound/soc/codecs/wm8960.c b/sound/soc/codecs/wm8960.c index 8dc1f3d..c4c0029 100644 --- a/sound/soc/codecs/wm8960.c +++ b/sound/soc/codecs/wm8960.c @@ -863,8 +863,7 @@ static int wm8960_hw_params(struct snd_pcm_substream *substream,
wm8960->is_stream_in_use[tx] = true;
- if (snd_soc_component_get_bias_level(component) == SND_SOC_BIAS_ON && - !wm8960->is_stream_in_use[!tx]) + if (!wm8960->is_stream_in_use[!tx]) return wm8960_configure_clocking(component);
return 0;