From: Florian Fainelli f.fainelli@gmail.com
[ Upstream commit b2ffc75e2e990b09903f9d15ccd53bc5f3a4217c ]
Commit 02a6efcab675 ("net: phy: allow scanning busses with missing phys") added a special condition to return -ENODEV in case -ENODEV or -EIO was returned from the first read of the MII_PHYSID1 register.
In case the MDIO bus data line pull-up is not strong enough, the MDIO bus controller will not flag this as a read error. This can happen when a pluggable daughter card is not connected and weak internal pull-ups are used (since that is the only option, otherwise the pins are floating).
The second read of MII_PHYSID2 will be correctly flagged an error though, but now we will return -EIO which will be treated as a hard error, thus preventing MDIO bus scanning loops to continue succesfully.
Apply the same logic to both register reads, thus allowing the scanning logic to proceed.
Fixes: 02a6efcab675 ("net: phy: allow scanning busses with missing phys") Reviewed-by: Andrew Lunn andrew@lunn.ch Signed-off-by: Florian Fainelli f.fainelli@gmail.com Signed-off-by: David S. Miller davem@davemloft.net Signed-off-by: Greg Kroah-Hartman gregkh@linuxfoundation.org --- drivers/net/phy/phy_device.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-)
diff --git a/drivers/net/phy/phy_device.c b/drivers/net/phy/phy_device.c index 634e8286e9b3..9ee52409b41d 100644 --- a/drivers/net/phy/phy_device.c +++ b/drivers/net/phy/phy_device.c @@ -606,8 +606,10 @@ static int get_phy_id(struct mii_bus *bus, int addr, u32 *phy_id,
/* Grab the bits from PHYIR2, and put them in the lower half */ phy_reg = mdiobus_read(bus, addr, MII_PHYSID2); - if (phy_reg < 0) - return -EIO; + if (phy_reg < 0) { + /* returning -ENODEV doesn't stop bus scanning */ + return (phy_reg == -EIO || phy_reg == -ENODEV) ? -ENODEV : -EIO; + }
*phy_id |= (phy_reg & 0xffff);