From: Suman Ghosh sumang@marvell.com
stable inclusion from stable-v6.6.4 commit f174a0dae5bc6da755368e4bcad6d86e06249ba4 category: bugfix bugzilla: https://gitee.com/openeuler/kernel/issues/I8N1WC
Reference: https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=...
--------------------------------
[ Upstream commit 4aa1d8f89b10cdc25a231dabf808d8935e0b137a ]
It is possible to add a ntuple rule which would like to direct packet to a VF whose number of queues are greater/less than its PF's queue numbers. For example a PF can have 2 Rx queues but a VF created on that PF can have 8 Rx queues. As of today, ntuple rule will reject rule because it is checking the requested queue number against PF's number of Rx queues. As a part of this fix if the action of a ntuple rule is to move a packet to a VF's queue then the check is removed. Also, a debug information is printed to aware user that it is user's responsibility to cross check if the requested queue number on that VF is a valid one.
Fixes: f0a1913f8a6f ("octeontx2-pf: Add support for ethtool ntuple filters") Signed-off-by: Suman Ghosh sumang@marvell.com Reviewed-by: Wojciech Drewek wojciech.drewek@intel.com Reviewed-by: Simon Horman horms@kernel.org Link: https://lore.kernel.org/r/20231121165624.3664182-1-sumang@marvell.com Signed-off-by: Paolo Abeni pabeni@redhat.com Signed-off-by: Sasha Levin sashal@kernel.org Signed-off-by: Zheng Zengkai zhengzengkai@huawei.com --- .../marvell/octeontx2/nic/otx2_flows.c | 20 ++++++++++++++++++- 1 file changed, 19 insertions(+), 1 deletion(-)
diff --git a/drivers/net/ethernet/marvell/octeontx2/nic/otx2_flows.c b/drivers/net/ethernet/marvell/octeontx2/nic/otx2_flows.c index 4762dbea64a1..97a71e9b8563 100644 --- a/drivers/net/ethernet/marvell/octeontx2/nic/otx2_flows.c +++ b/drivers/net/ethernet/marvell/octeontx2/nic/otx2_flows.c @@ -1088,6 +1088,7 @@ int otx2_add_flow(struct otx2_nic *pfvf, struct ethtool_rxnfc *nfc) struct ethhdr *eth_hdr; bool new = false; int err = 0; + u64 vf_num; u32 ring;
if (!flow_cfg->max_flows) { @@ -1100,7 +1101,21 @@ int otx2_add_flow(struct otx2_nic *pfvf, struct ethtool_rxnfc *nfc) if (!(pfvf->flags & OTX2_FLAG_NTUPLE_SUPPORT)) return -ENOMEM;
- if (ring >= pfvf->hw.rx_queues && fsp->ring_cookie != RX_CLS_FLOW_DISC) + /* Number of queues on a VF can be greater or less than + * the PF's queue. Hence no need to check for the + * queue count. Hence no need to check queue count if PF + * is installing for its VF. Below is the expected vf_num value + * based on the ethtool commands. + * + * e.g. + * 1. ethtool -U <netdev> ... action -1 ==> vf_num:255 + * 2. ethtool -U <netdev> ... action <queue_num> ==> vf_num:0 + * 3. ethtool -U <netdev> ... vf <vf_idx> queue <queue_num> ==> + * vf_num:vf_idx+1 + */ + vf_num = ethtool_get_flow_spec_ring_vf(fsp->ring_cookie); + if (!is_otx2_vf(pfvf->pcifunc) && !vf_num && + ring >= pfvf->hw.rx_queues && fsp->ring_cookie != RX_CLS_FLOW_DISC) return -EINVAL;
if (fsp->location >= otx2_get_maxflows(flow_cfg)) @@ -1182,6 +1197,9 @@ int otx2_add_flow(struct otx2_nic *pfvf, struct ethtool_rxnfc *nfc) flow_cfg->nr_flows++; }
+ if (flow->is_vf) + netdev_info(pfvf->netdev, + "Make sure that VF's queue number is within its queue limit\n"); return 0; }