On Thu, Jan 07, 2021 at 04:36:29PM +0800, Weihang Li wrote:
From: Yangyang Li liyangyang20@huawei.com
In order to improve performance by balancing the load between different banks of cache, the CQC cache is desigend to choose one of 4 banks according to lower 2 bits of CQN. The hns driver needs to count the number of CQ on each bank and then assigns the CQ being created to the bank with the minimum load first.
Signed-off-by: Yangyang Li liyangyang20@huawei.com Signed-off-by: Weihang Li liweihang@huawei.com
Changes since v1:
- Change GFP_ATOMIC to GFP_KERNEL as there is a chance of memory allocation failure, and change the spin lock to mutex lock because ida_alloc_range() may sleep.
- Link: https://patchwork.kernel.org/project/linux-rdma/patch/1609742115-47270-1-git...
drivers/infiniband/hw/hns/hns_roce_cq.c | 115 +++++++++++++++++++++++----- drivers/infiniband/hw/hns/hns_roce_device.h | 10 ++- drivers/infiniband/hw/hns/hns_roce_main.c | 8 +- 3 files changed, 105 insertions(+), 28 deletions(-)
Applied to for-next, thanks